kernel
This commit is contained in:
parent
b59f84ee36
commit
cfab1d3ce7
83468 changed files with 37938688 additions and 0 deletions
56
linux-6.8.1/Documentation/hwmon/ina238.rst
Normal file
56
linux-6.8.1/Documentation/hwmon/ina238.rst
Normal file
|
@ -0,0 +1,56 @@
|
|||
.. SPDX-License-Identifier: GPL-2.0-only
|
||||
|
||||
Kernel driver ina238
|
||||
====================
|
||||
|
||||
Supported chips:
|
||||
|
||||
* Texas Instruments INA238
|
||||
|
||||
Prefix: 'ina238'
|
||||
|
||||
Addresses: I2C 0x40 - 0x4f
|
||||
|
||||
Datasheet:
|
||||
https://www.ti.com/lit/gpn/ina238
|
||||
|
||||
Author: Nathan Rossi <nathan.rossi@digi.com>
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
The INA238 is a current shunt, power and temperature monitor with an I2C
|
||||
interface. It includes a number of programmable functions including alerts,
|
||||
conversion rate, sample averaging and selectable shunt voltage accuracy.
|
||||
|
||||
The shunt value in micro-ohms can be set via platform data or device tree at
|
||||
compile-time or via the shunt_resistor attribute in sysfs at run-time. Please
|
||||
refer to the Documentation/devicetree/bindings/hwmon/ti,ina2xx.yaml for bindings
|
||||
if the device tree is used.
|
||||
|
||||
Sysfs entries
|
||||
-------------
|
||||
|
||||
======================= =======================================================
|
||||
in0_input Shunt voltage (mV)
|
||||
in0_min Minimum shunt voltage threshold (mV)
|
||||
in0_min_alarm Minimum shunt voltage alarm
|
||||
in0_max Maximum shunt voltage threshold (mV)
|
||||
in0_max_alarm Maximum shunt voltage alarm
|
||||
|
||||
in1_input Bus voltage (mV)
|
||||
in1_min Minimum bus voltage threshold (mV)
|
||||
in1_min_alarm Minimum shunt voltage alarm
|
||||
in1_max Maximum bus voltage threshold (mV)
|
||||
in1_max_alarm Maximum shunt voltage alarm
|
||||
|
||||
power1_input Power measurement (uW)
|
||||
power1_max Maximum power threshold (uW)
|
||||
power1_max_alarm Maximum power alarm
|
||||
|
||||
curr1_input Current measurement (mA)
|
||||
|
||||
temp1_input Die temperature measurement (mC)
|
||||
temp1_max Maximum die temperature threshold (mC)
|
||||
temp1_max_alarm Maximum die temperature alarm
|
||||
======================= =======================================================
|